S6720S-26Q-SI-24S-AC
Version Mapping
Table 4-124 lists the mapping between the S6720S-26Q-SI-24S-AC chassis and software versions.
Appearance and Structure
1 |
Twenty-four 10GE SFP+ ports Applicable modules and cables:
|
2 |
Two 40GE QSFP+ ports Applicable modules and cables:
NOTE:
A 40GE QSFP+ optical port can be split into four 10GE ports. |
3 |
One PNP button NOTICE:
Applicable in V200R012C00 and later versions: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
4 |
One ETH management port |
5 |
One console port |
6 |
One USB port |
7 |
Ground screw NOTE:
It is used with a ground cable.
|
8 |
ESN label NOTE:
You can draw it out to view the ESN and MAC address of the switch. |
9 |
Fan slot NOTE:
Applicable fan module:Â FAN-046A-B Fan Module |
10 |
Power module slot 2 NOTE:
Applicable power modules:
|
11 |
Power module slot 1 NOTE:
Applicable power modules:
|
– |
– |
Port Description
10GE SFP+ port
40GE QSFP+ port
Console port
ETH management port
Attribute |
Description |
---|---|
Connector type |
RJ45 |
Standards compliance |
IEEE802.3 |
Working mode |
10/100 Mbit/s auto-sensing |
Maximum transmission distance |
100 m |
In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see “First Login to a Switch” in the Configuration Guide – Basic Configuration. If you have logged in to the device for the first time by pressing and holding the MODE button for 6 seconds or longer and saved the configuration, the default configuration on the ETH port will be cleared. In this case, you cannot log in to the switch for the first time through the ETH port. You are advised to log in to the switch for the first time through the ETH port.
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S6720S-26Q-SI-24S-AC has the same types of indicators as the S6720-26Q-SI-24S-AC. For details, see Indicator Description.
Power Supply Configuration
The S6720S-26Q-SI-24S-AC uses pluggable power modules. It can be configured with a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
Heat Dissipation
The S6720S-26Q-SI-24S-AC uses a pluggable fan module for forced air cooling. Air flows in from the left, right, and front sides, and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-129 lists specifications of the S6720S-26Q-SI-24S-AC.
Item |
Description |
---|---|
Memory (RAM) |
1 GB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
41.9 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
NA |
Power supply surge protection |
|
Dimensions (H x W x D) |
|
Weight (including package) |
8.9 kg (19.62 lb) |
Stack ports |
|
RTC |
Supported |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz -36 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
97 W |
Typical power consumption (30% of traffic load, tested according to ATIS standard) |
68.4 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Short-term operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 57 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
|
Certification |
|
Part number |
98010691 |
Reviews
There are no reviews yet.