Table 4-1523 Basic information about the S5735-L32ST4X-A1

Item Details
Description S5735-L32ST4X-A1 (24*GE SFP ports, 8*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power, front access)
Part Number 98011396
Model S5735-L32ST4X-A1
First supported version V200R020C10

Components

Figure 4-555 S5735-L32ST4X-A1 appearance

1

Twenty-four 100/1000BASE-X ports

2

Eight 10/100/1000BASE-T ports

3

Four 10GE SFP+ ports

4

One console port

5

One USB port

6

One PNP button

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

7

AC socket

NOTE:

It is used with an AC power cable.

8

Jack for AC power cable locking strap

NOTE:

The AC power cable locking strap is not delivered with the switch.

9

Ground screw

NOTE:

It is used with a ground cable.

Ports

Table 4-1524 Ports on the S5735-L32ST4X-A1

Port Connector Type Description Available Components
10/100/1000BASE-T port RJ45 A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s.

Ethernet cable

100/1000BASE-X port SFP A 100/1000BASE-X port can send and receive data at 100 Mbit/s or 1000 Mbit/s.
10GE SFP+ optical port SFP+ A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s.
Console port RJ45 The console port is connected to a console for on-site configuration.

Console cable

USB port USB 2.0 Type A

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

USB flash drive

Indicators and Buttons

Figure 4-556 Indicators on the S5735-L32ST4X-A1
Table 4-1525 Description of indicators on the switch

No.

Indicator

Name

Color

Status

Description

1

PWR

Power module indicator

Off

The switch is powered off.

Green

Steady on

The system power supply is normal.

2

SYS

System status indicator

Off

The system is not running.

Green

Fast blinking

The system is starting.

Green

Steady on

During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds.

Green

Slow blinking

The system is running normally.

Red

Steady on

The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated.

3

MST

Stack indicator

Off

  • If you are not changing the indicator mode (default): The switch is a standby or slave switch in a stack or the stacking function is not enabled on the switch.
  • If you are changing the indicator mode: The stack mode is not selected.

Green

Steady on

The stack mode is selected. The switch is a standby or slave switch in a stack, and the service port indicators show the stack ID of the switch.

Green

Blinking

  • If you are not changing the indicator mode (default): The switch is the master switch in a stack or a standalone switch with the stacking function enabled.
  • If you are changing the indicator mode: The stack mode is selected. The switch is the master switch in a stack or a standalone switch, and the service port indicators show the stack ID of the master switch. After 45 seconds, the service port indicators automatically restore to the status mode.

4

SPEED

Speed indicator

Off

The speed mode is not selected.

Green

Steady on

The speed mode is selected, and service port indicators show the speed of each port.

5

MODE

Mode switch button

  • When you press this button once, the service port indicators change to the stack mode and show the stack ID of the local switch.
  • When you press this button a second time, the service port indicators change to the speed mode and show the speed of each service port.
  • When you press this button a third time, the service port indicators restore to the default mode and show the connection status and link activity of each service port.

If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the SPEED indicator is off.

NOTE:

Hold down the mode switch button for 6s and release it to start the web initial login mode. Either of the following situations will occur:

  • If the switch has no configuration file, the system attempts to enter the web initial login mode. In this mode, the status of mode indicators is as follows:
    • If the system enters the web initial login mode successfully, all mode indicators turn green and stay on for a maximum of 10 minutes.
    • If the system fails to enter the initial login mode, all mode indicators fast blink for 10 seconds and then restore the default status.
  • If the switch has a configuration file, the system cannot enter the web initial login mode. In this case, all mode indicators fast blink for 10s, and then return to the default states.

6

Service port indicator

Meanings of service port indicators vary in different modes. For details, see Table 4-1526 and Table 4-1527.

NOTE:

If a power failure occurs on a device’s PCB board, indicators of the last four optical ports on the device’s front panel blink green cyclically at an interval of 1 second, with each indicator illuminating for 0.25 seconds.

7

ID

ID indicator

Off

The ID indicator is not used (default state).

Blue

Steady on

The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain.

8

USB

USB-based deployment indicator

Off

  • No USB flash drive is connected to the switch.
  • The USB port is damaged.
  • The indicator is damaged.
  • The USB flash drive does not have any configuration file and cannot be used for deployment.
  • The switch has been upgraded using the USB flash drive and is restarting.

Green

Steady on

A USB-based deployment has been completed.

Green

Fast blinking

The system is reading data from a USB flash drive.

Green

Slow blinking

The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch.

Red

Fast blinking

An error has occurred when the system is executing the configuration file or reading data from the USB flash drive.

Table 4-1526 Description of service port indicators in different modes (one indicator for each port)

Display Mode

Color

Status

Description

Default mode

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Green

Blinking

The port is sending or receiving data.

Speed mode

Off

The port is not connected or has been shut down.

Green

Steady on

1000M/10GE port: The port is operating at 1000 Mbit/s.

Green

Blinking

1000M/10GE port: The port is operating at 10 Gbit/s.

Table 4-1527 Description of service port indicators in different modes (two indicators for each port)

Display Mode

Color

Status

Description

Default mode

Off

The port is not connected or has been shut down.

Green

Steady on

A link has been established on the port.

Yellow

Blinking

The port is sending or receiving data.

MST stack mode

Off

Port indicators do not show the stack ID of the switch.

Green and yellow

Steady on

The switch is not the master switch in a stack.

  • If the indicator of a port is steady on, the number of this port is the stack ID of the switch.

  • If the indicators of ports 1 to 9 are steady on, the stack ID of the switch is 0.

Green and yellow

Blinking

The switch is the master switch in a stack.

  • If the indicator of a port is blinking, the number of this port is the stack ID of the switch.

  • If the indicators of ports 1 to 9 are blinking, the stack ID of the switch is 0.

Speed mode

Off

The port is not connected or has been shut down.

Green and yellow

Steady on

10M/100M/1000M port: The port is operating at 10 Mbit/s or 100 Mbit/s.

100M/1000M port: The port is operating at 100 Mbit/s.

Green and yellow

Blinking

10M/100M/1000M port: The port is operating at 1000 Mbit/s.

100M/1000M port: The port is operating at 1000 Mbit/s.

Power Supply System

The switch has a built-in AC power module and does not support pluggable power modules.

Heat Dissipation System

The switch has two built-in fans for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 4-1528 Technical specifications of the S5735-L32ST4X-A1

Item Specification
Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.)
Chassis height [U] 1 U
Weight without packaging [kg(lb)] 2.88 kg (6.35 lb)
Weight with packaging [kg(lb)] 4.03 kg (8.89 lb)
Typical power consumption [W] 53.2 W
Typical heat dissipation [BTU/hour] 181.52 BTU/hour
Maximum power consumption [W] 66.8 W
Maximum heat dissipation [BTU/hour] 227.93 BTU/hour
MTBF [year] 58.44 year
MTTR [hour] 2 hour
Availability >0.99999
Noise at normal temperature (acoustic power) [dB(A)] 46.8 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 35 dB(A)
Number of card slots 0
Number of power slots 0
Number of fans modules 2
Redundant power supply Not supported
Long-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
Short-term operating temperature [°C(°F)] -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:

  • The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.
  • The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.
  • The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.

The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.

The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.

Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH] 5% to 95%, noncondensing
Long-term operating altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode AC built-in
Rated input voltage [V]
  • AC input: 100 V AC to 240 V AC, 50/60 Hz
  • High-Voltage DC input: 240 V DC
Input voltage range [V]
  • AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz
  • High-Voltage DC input: 190 V DC to 290 V DC
Maximum input current [A] 2 A
Memory 512 MB
Flash memory 512 MB
Console port RJ45
Eth Management port Not supported
USB Supported
RTC Not supported
RPS input Not supported
Service port surge protection [kV] Common mode: ±7 kV
Power supply surge protection [kV] ±6 kV in differential mode, ±6 kV in common mode
Types of fans Built-in
Heat dissipation mode Heat dissipation with fan, intelligent fan speed adjustment
Airflow direction Air intake from left and front, air exhaustion from right
PoE Not supported
Certification

EMC certification

Safety certification

Manufacturing certification

Reviews

There are no reviews yet.

Be the first to review “S5735-L32ST4X-A1”
Review now to get coupon!

Your email address will not be published. Required fields are marked *

Back to Top
Select your currency
AED United Arab Emirates dirham
Product has been added to your cart